The heart can’t pump blood that doesn’t reach it, and blood can’t come back unless the heart pumps it out. In the steady state, what leaves (the cardiac output) has to equal what comes back (the venous return). The Guyton curves draw both on one graph, and the point where they cross is where the system settles. They let you predict what happens to cardiac output and right atrial pressure after any change: a hemorrhage, a transfusion, a drug. If you know which curve moves and in which direction, you know where the new steady state will be.
1. Two curves against right atrial pressure
Both curves share the same horizontal axis: right atrial pressure. But that pressure affects each of them in the opposite direction.
The cardiac function curve
It shows how much the heart pumps depending on how much it fills. The higher the right atrial pressure, the more the ventricle fills and, by Frank-Starling, the more blood it ejects. The curve rises with atrial pressure until it reaches a plateau of about 9 L/min, when the heart can’t give any more.
The properties of the heart can move it: contractility, heart rate and afterload. A stronger heart has a higher curve.
The venous return curve
It shows how much blood comes back to the heart. Blood returns because there is a gradient: it flows from the pressure in the peripheral veins to the pressure in the right atrium. That is why this curve is inverse: the lower the atrial pressure, the larger the gradient and the more blood returns.
It has a limit: when atrial pressure falls below 0 mmHg, the large veins entering the chest collapse, and lowering it further no longer increases venous return. The curve flattens.
The curve moves in two ways, covered in the next sections: where it crosses the X-axis is set by the mean systemic pressure (blood volume and venous compliance), and its slope is set by total peripheral resistance.
| Curve | Axes | Shape | What moves it |
|---|---|---|---|
| Cardiac function | Cardiac output against right atrial pressure (independent variable) | Rises with atrial pressure (Frank-Starling) to a plateau of ~9 L/min | Contractility, heart rate and afterload |
| Venous return (vascular function) | Venous return against right atrial pressure | Inverse: the lower the atrial pressure, the larger the gradient and the more return; it flattens below 0 mmHg (venous collapse) | Slope: total peripheral resistance. X-intercept: mean systemic pressure (blood volume and venous compliance) |
2. Mean systemic pressure
If the heart suddenly stopped, blood would redistribute until the pressure was the same in every vessel. That pressure is the mean systemic pressure, and it is about 7 mmHg. With no pressure differences there is no flow, so it is the point on the curve where venous return is zero: the X-intercept.
Stressed and unstressed volume
What does that pressure depend on? On how much blood stretches the vessel walls. Here it helps to tell apart two kinds of volume:
- The unstressed volume is the blood that simply fills the vessels without stretching them, so it generates no pressure. It sits mostly in the veins, which are very compliant. Of 5 L of blood, about 4 L are unstressed.
- The stressed volume is the blood that, beyond filling, stretches the walls and generates pressure. It sits mostly in the arteries.
Only the stressed volume generates mean systemic pressure. So there are two ways to raise it: add blood, or turn unstressed volume into stressed volume.
What moves it
- If blood volume rises (fluids, transfusion) or the veins constrict (↓ venous compliance), there is more stressed volume, mean systemic pressure rises, and the venous return curve shifts in parallel to the right.
- If blood volume falls (hemorrhage) or the veins dilate (↑ venous compliance), mean systemic pressure falls, and the curve shifts to the left.
High-yield: blood volume and venous tone shift the venous return curve in parallel; arteriolar resistance rotates it.
3. Total peripheral resistance
The resistance of the arterioles has a double effect, because it touches both curves at once.
If resistance falls (the arterioles dilate):
- Blood passes more easily from the arteries to the veins, and more blood returns at the same atrial pressure. The venous return curve rotates clockwise (it becomes steeper), without moving its X-intercept.
- The heart ejects blood more easily (less afterload), and the cardiac curve rises.
- Result: ↑ cardiac output.
If resistance rises, the opposite happens: the venous return curve rotates counterclockwise, the cardiac curve falls, and cardiac output drops.
In both cases, right atrial pressure changes little, because the effects on the two curves push it in opposite directions and offset each other. Mean systemic pressure, on the other hand, is taken as fixed: resistance changes the slope of the venous return curve, not where it crosses the X-axis.
4. Scenarios
With these rules you can predict the new steady state in any situation. Just ask which curve moves:
- If only volume changes, the venous return curve moves. A hemorrhage shifts it to the left, and the operating point drops down and to the left: less cardiac output and lower atrial pressure. A transfusion does the opposite.
- If only the strength of the heart changes, the cardiac curve moves. A positive inotrope like digoxin raises it, and the operating point moves up and to the left: more output with lower atrial pressure, because the heart empties the atrium better.
- In chronic systolic heart failure both move: the cardiac curve falls (a weak heart), and the kidney retains fluid, so the venous return curve shifts to the right. The operating point ends up down and to the right: low output with high filling pressures, that is, congestion.
- If resistance changes, both curves move at once, as in section 3.
| Situation | Cardiac curve | Venous return | New steady state |
|---|---|---|---|
| Acute hemorrhage | No change | To the left | Down and to the left: ↓ output, ↓ atrial pressure |
| IV fluids, transfusion | No change | To the right | Up and to the right |
| Digoxin (positive inotrope) | Rises | No change | Up and to the left: ↑ output, ↓ atrial pressure |
| Negative inotrope | Falls | No change | Down and to the right |
| Chronic systolic HF | Falls | Flattens and its intercept moves right (retention) | Down and to the right: low output with congestion |
| Phenylephrine (↑ TPR) | Falls | Less steep | Lower |
| Hydralazine (↓ TPR) | Rises | Steeper | Higher |
| Large AV fistula | Rises | Steeper | Very high output (high-output HF) |
5. Mean arterial pressure
The formula MAP = cardiac output × total peripheral resistance seems to suggest that, if resistance doubles, pressure doubles. But output and resistance aren’t independent: as section 3 showed, when resistance rises, output falls. If resistance doubles, output is almost halved, and MAP rises only modestly.
The same reasoning explains the reverse: a large arteriovenous fistula lowers resistance so much that arterial pressure can fall, even though output rises enormously: resistance falls more than output rises.
Pearl: a positive inotrope raises cardiac output and lowers right atrial pressure; giving volume raises output and raises atrial pressure. That is how you tell them apart on the curves.