medical games (mg.)

Theory · Parameters of cardiac function

Parameters of cardiac function

Updated

All of the heart’s work comes down to one number: the cardiac output, how much blood it pumps per minute. And output depends on only two things: how many times it beats (heart rate) and how much blood it ejects with each beat (stroke volume). Stroke volume, in turn, depends on three: how full the ventricle got (preload), how much resistance it ejects against (afterload) and how forcefully it contracts (contractility). With these five pieces you can understand almost all of cardiac physiology and pharmacology.

1. Stroke volume

How much leaves with each beat

At the end of diastole the ventricle is full: that is the end-diastolic volume (EDV), about 140 mL. At the end of systole it doesn’t empty completely; what remains is the end-systolic volume (ESV), about 70 mL. What left is the difference:

Stroke volume (SV) = EDV − ESV

The ejection fraction tells you what proportion of its contents the ventricle ejects with each beat: EF = SV / EDV, normally about 55%. It is the most widely used measure of the ventricle’s strength.

Each of the two volumes tells a different story. EDV reflects preload: how much blood arrived. ESV reflects contractility, but inversely: a strong ventricle empties more and leaves a small ESV.

The three determinants

Determinant What it is Effect of raising it
Preload EDV (venous return) ↑ SV (Frank-Starling)
Afterload What the LV must overcome (resistance, aortic pressure) ↑ ESV → ↓ SV
Contractility Force at a given preload ↓ ESV → ↑ SV

Preload is how much the ventricle is stretched before it contracts, and it is measured as the EDV. It depends mainly on venous return. More preload, more stroke volume (the Frank-Starling law, section 3).

Afterload is the resistance the ventricle has to overcome to open the aortic valve and eject blood: in practice, aortic pressure and peripheral resistance. If it rises, the ventricle has a harder time emptying, more blood stays inside (↑ ESV) and SV falls.

Contractility is the muscle’s intrinsic force at a given preload. If it rises (with sympathetic stimulation, for example), the ventricle empties more (↓ ESV) and SV rises.

The healthy heart versus the failing heart

In a healthy heart, preload compensates for changes in afterload: if aortic pressure rises, less blood leaves on one beat, more stays inside, the next beat starts with more preload and contracts more forcefully. SV recovers.

In heart failure, by contrast, the ventricle is already stretched to the maximum and has no such reserve: afterload dominates. Small rises in resistance lower SV a lot. That is why vasodilators, which reduce afterload, help these patients so much.

The law of Laplace

The tension the ventricular wall bears depends on its shape:

Wall tension = pressure × radius / (2 × thickness)

It is like a balloon: the bigger it is, the tenser the wall. A dilated LV (large radius) bears more tension with each beat and therefore uses more O₂. A thicker wall spreads the tension, which is why hypertrophy is a way to reduce it: it is the heart’s response to a pressure overload.

2. Heart rate

At rest the sinus node is held back by the vagus nerve. To raise the heart rate, the body does two things at once: it releases the brake (lowers vagal tone) and presses the accelerator (raises sympathetic tone).

A faster rate raises output, but only up to a point. When the heart beats faster, the cycle shortens, and what shortens most is diastole. That has two consequences:

  • The ventricle has less time to fill, so preload and SV fall.
  • The LV is perfused in diastole (in systole the contracting muscle squeezes its own coronaries), so coronary perfusion falls just when the heart is working hardest.

At very high rates SV falls so much that output drops instead of rising. A person’s maximal heart rate depends on age; the classic estimate is 220 − age.

Cardiac output = heart rate × stroke volume

3. The Frank-Starling law

The principle

The heart has an automatic mechanism for pumping everything it receives: the more it fills, the harder it contracts. More preload gives more stroke volume. Thanks to this, in the steady state, cardiac output equals venous return: the heart ejects exactly what it receives, with no nervous signal needed. It also keeps the two ventricles balanced: if the right pumps a little more, the left receives more blood and pumps more too.

Why it works

It all starts in the sarcomere. More venous return fills the ventricle more (↑ EDV), which stretches each myocyte further and lengthens its sarcomeres. At a greater length, the actin and myosin filaments sit in a more favorable position to interact, and the fiber generates more active tension and shortens faster.

The curve

On the Frank-Starling curve, the x-axis is preload (end-diastolic pressure or volume) and the y-axis is stroke volume. There are two ways to move:

  • Moving along the curve: if preload changes, the heart shifts to another point on the same curve.
  • Changing curves: if contractility or afterload changes, the whole curve shifts. More contractility (or less afterload) gives a higher curve: more SV at the same preload.

High-yield: a positive inotrope (digoxin, dobutamine) shifts the curve up; a diuretic moves the point to the left along the same curve.

4. Cardiac output and blood pressure

Output can be calculated two ways. Directly, by multiplying heart rate × stroke volume. And indirectly, with the Fick principle: if you know how much oxygen the body uses per minute and how much oxygen each milliliter of blood gives up passing through the tissues (the arteriovenous O₂ difference), you can work out how much blood had to pass.

Mean arterial pressure (MAP) is the pressure that drives blood into the tissues, and it behaves as in any circuit: it is flow times resistance, that is, cardiac output × peripheral resistance. That resistance comes mostly from the arterioles, the vessels that can open and close.

If you only have the arm pressure, MAP is estimated as 1/3 of systolic + 2/3 of diastolic. Diastolic counts double because the heart spends about two-thirds of the cycle in diastole. The difference between the two is the pulse pressure.

Formula
Cardiac output Heart rate × stroke volume
Fick O₂ consumption / arteriovenous O₂ difference
MAP Cardiac output × peripheral resistance
MAP (from pressures) 1/3 systolic + 2/3 diastolic = diastolic + PP/3
Pulse pressure Systolic − diastolic

5. Coronary flow

The heart feeds the whole body, but it also has to feed itself, and it does so under difficult conditions.

First, the LV receives its flow mainly in diastole. In systole, the contracting muscle squeezes the coronaries running through it and flow almost stops. That is why tachycardia, which shortens diastole, is so bad for an ischemic heart.

Second, the myocardium already extracts a high and nearly fixed proportion of the O₂ in the blood reaching it, even at rest. Other organs, when they need more oxygen, can extract more from the same blood; the heart doesn’t have that margin. It can only respond by increasing flow.

To do that, the coronaries have metabolic autoregulation: when the heart works harder, local hypoxia and the adenosine released by the muscle itself dilate the coronaries and increase flow exactly where it is needed. The sympathetic system has little influence.

Pearl: the heart can’t extract more O₂ from the blood; if its demand rises, the only way out is more flow. That is why a coronary stenosis causes symptoms on exertion.

Source: Costanzo, Physiology, 6th ed., ch. 4 (Cardiac contraction, stroke volume, cardiac output, Frank-Starling, cardiac work, the Fick principle and the coronary circulation); Harrison’s Principles of Internal Medicine, 21st ed., ch. 273 (myocardial O₂ extraction); Tanaka et al., J Am Coll Cardiol 2001;37:153 (maximal heart rate).